314: Topical Ocular BL1332 TRPV1 Antagonist: Safety and Tolerability in Healthy Volunteers
Topic: Clinical Science
Subtopic: Non-specific to any diagnosis, Pharmacological treatments, Drug development, Treatment/management
Background and Aims: Ocular surface pain (OSP) is a clinical challenge, associated with dry eye, surgery, and neuropathic syndromes. Current therapies targeting inflammation and nerve dysfunction often provide incomplete relief. The transient receptor potential vanilloid 1 (TRPV1) channel mediates nociceptive signalling through heat, acidity and inflammation, leading to peripheral sensitization of corneal nerves. BL1332, a potent, non-competitive TRPV1 antagonist, is being developed as a topical eye drop for OSP. Non-clinical studies demonstrated high ocular potency, in-vivo efficacy in acute corneal pain and low systemic exposure. This first-in-human study evaluated the ocular safety and tolerability of BL1332 compared with vehicle in healthy volunteers.
Methods: This was a double-masked, randomized, vehicle-controlled, sequential-cohort, dose-escalation study of BL1332 eye drops in domiciled healthy volunteers. A total of 24 volunteers were randomized in a 3:1 ratio, with 6 volunteers randomized to BL1332 (low, medium, or high dose) and 2 volunteers to vehicle within each of the three cohorts. Study treatment was instilled 4 times over a single day at 4-hour intervals, followed by three days of safety assessments. Extensive medical and ocular examinations were conducted to assess safety and tolerability. Dose-limiting toxicity (DLT) criteria were prespecified, and cohort escalation decisions were adjudicated by a data monitoring committee (DMC).
Results: Baseline characteristics were comparable across all treatment groups and dose cohorts, with no clinically meaningful differences observed in key parameters including demographics, age, sex, and BMI. No DLT were observed, and no Serious Adverse Events were reported. Only one treatment emergent AE was reported, which was mild in severity and unrelated to study treatment. Esthesiometry analysis showed stable corneal sensitivity across all concentrations of BL1332 and across all time points. No treatment-related changes were observed in any ocular safety endpoints, including blink rate, tear production, or corneal fluorescein staining, supporting the overall ocular safety and tolerability of BL1332.
Conclusions: This phase 1 clinical study showed that topical ocular BL1332—a novel selective potent TRPV1 antagonist—is safe and tolerable at all tested doses, with no DLTs occurring from any of the concentrations evaluated, and importantly, not hindering the ocular surface’s normal defence mechanisms. BL1332 confirmed safety and tolerability as a topical ophthalmic medicine to develop further for the treatment of ocular surface pain which presents a significant unmet clinical need.
References: • Stasi K, Alshare Q, Jain M, Wald M, Li Y. Topical Ocular TRPV1 Antagonist SAF312 (Libvatrep) Demonstrates Safety, Low Systemic Exposure, and No Anesthetic Effect in Healthy Participants. Transl Vis Sci Technol. 2022 Nov 1;11(11):15.
• Thompson V, Moshirfar M, Clinch T, Scoper S, Linn SH, McIntosh A, Li Y, Eaton M, Ferriere M, Stasi K. Topical Ocular TRPV1 Antagonist SAF312 (Libvatrep) for Postoperative Pain After Photorefractive Keratectomy. Transl Vis Sci Technol. 2023 Mar 1;12(3):7.
• Non-clinical studies: Data on File.
Presenting Author: Sameena Haque
Submitting Author: Sameena Haque
Senior Author: Sameena Haque
IASP 2026 Global Year theme of Neuropathic Pain: Yes
Co-Authors:
- Lakshmi Rajagopalan - Bausch and Lomb
- Kevin Kerr - Bausch and Lomb
- Mayssa Attar - Bausch and Lomb
Topical Ocular BL1332 TRPV1 Antagonist: Safety and Tolerability in Healthy Volunteers
Category
Poster
Description
Session Type: Posters
Room: Exhibit Hall EH102-103
27/10/2026
09:30 AM - 11:00 AM