616: Ultrasound-guided Fluoroscopic-verified Lumbar TFESI: A Clinical Evaluation of Technique
Topic: Education, Societal Impact, and Others
Subtopic: Methodology others
Background and Aims: Lumbar TFESI constitutes a high-precision perineural intervention for the management of lumbo-sacral radiculopathy. Conventional fluoroscopy-guided TFESI while considered the reference standard for epidural confirmation, is inherently dependent on ionizing radiation and contrast utilization, raising cumulative occupational and patient-specific radiobiological concerns. A hybrid paradigm integrating ultrasound-guided needle navigation with minimal fluoroscopic contrast confirmation may represent a strategic convergence of precision, safety and radiation attenuation. The aim is to prospectively determine whether a Doppler-integrated, ultrasound-assisted hybrid lumbar TFESI technique significantly attenuates fluoroscopic exposure parameters (fluoroscopy time) while preserving procedural accuracy, neurovascular safety and clinical analgesic efficacy when compared with conventional fluoroscopy-guided TFESI.
Methods: All patients were evaluated and enrolled. The level of TFESI was selected by a single experienced pain medicine practitioner based on clinical findings and correlated MRI images. A portable ultrasound machine with a 2–5 MHz curved probe was used. A 23-G, 90 mm needle was inserted at a 45° angle using an in-plane approach for real-time visualization. After contacting the lateral facet, the needle was withdrawn slightly, redirected, and advanced into the foramen. Needle placement was confirmed with fluoroscopy and contrast spread. Patients were monitored for attempts, adjustments, insertion time, radiation exposure, complications, and assigned ultrasound visibility scores.
Results: Number of attempts for localization of transforaminal space in 85% of the patients was one and two in 15% of the patients, number of adjustments per attempt was 5.3, average time taken for TFESI in patients in one-attempt group was 973 ± 93 s and 1506 ± 65 s in two attempt group. The average exposure time of fluoroscope per person was 17.5 ± 2.5 s. Bony cortex contacted in 75% of cases, no complications noted. The UVS was 2.7 per case with no visibility of pulsations of cauda equina in any case, probably due to adult patients in the study.
Conclusions: Lumbar TFESI can be safely and effectively performed under US guidance but FL confirmation is required at this stage. Further studies and better US technology are required to eliminate fluoroscope dependence; however, US guidance has reduced radiation exposure to a significant level in this study.
References: 1. Kothari K, Sahu DK. Ultrasonography versus uoroscopy in modern pain management. Indian J Pain 2016;30:71-6.
2. Karmakar MK, Li X, Ho AM, Kwok WH, Chui PT. Real-time ultrasound-guided paramedian epidural access: Evaluation of a novel in-plane technique. Br J Anaesth 2009;102:845-54.
3. Fritz J, Niemeyer T, Clasen S, Wiskirchen J, Tepe G, Kastler B, et al. Management of chronic low back pain: Rationales, principles, and targets of imaging-guided spinal injections. Radiographics 2007;27:1751-71.
4. Silbergleit R, Mehta BA, Sanders WP, Talati SJ. Imaging-guided injection techniques with fluoroscopy and CT for spinal pain management. Radiographics 2001;21:927-39.
5. Galiano K, Obwegeser AA, Bodner G, Freund M, Maurer H, Kamelger FS, et al. Ultrasound guidance for facet joint injections in the lumbar spine: A computed tomography-controlled feasibility study. Anesth Analg 2005;101:579-83.
6. Galiano K, Obwegeser AA, Bodner G, Freund M, Maurer H, Kamelger FS, et al. Real-time sonographic imaging for periradicular injections in the lumbar spine: A sonographic anatomic study of a new technique. J Ultrasound Med 2005;24:33-8
7. Galiano K, Obwegeser AA, Bale R, Harlander C, Schatzer R, Schocke M, et al. Ultrasound-guided and CT-navigation-assisted periradicular and facet joint injections in the lumbar and cervical spine: A new teaching tool to recognize the sonoanatomic pattern. Reg Anesth Pain Med 2007;32:254-7.
8. Gofeld M, Bristow SJ, Chiu SC, McQueen CK, Bollag L. Ultrasound-guided lumbar transforaminal injections: Feasibility and validation study. Spine (Phila Pa 1976) 2012;37:808‑12.
9. Lie J, Patel S. Ultrasound for obstetric neuraxial anesthetic procedures: Practical and useful? J Obstet Anaesth Crit Care 2015;5:49-53.
10. Grau T, Leipold RW, Fatehi S, Martin E, Motsch J. Real-time ultrasonic observation of combined spinal-epidural anaesthesia. Eur J Anaesthesiol 2004;21:25-31.
11. Kim D, Choi D, Kim C, Kim J, Choi Y. Transverse process and needles of medial branch block to facet joint as landmarks for ultrasound-guided selective nerve root block. Clin Orthop Surg 2013;5:44-8.
12. Loizides A, Gruber H, Peer S, Galiano K, Bale R, Obernauer J. Ultrasound guided versus CT-controlled pararadicular injections in the lumbar spine: A prospective randomized clinical trial. AJNR Am J Neuroradiol 2013;34:466-70.
13. Yang G, Liu J, Ma L, Cai Z, Meng C, Qi S, et al. Ultrasound-guided versus fluoroscopy‑controlled lumbar transforaminal epidural injections: A prospective randomized clinical trial. Clin J Pain 2016;32:103-8
Presenting Author: DR ASHWINI GUPTA
Submitting Author: ashwini gupta
Senior Author: DR DINESH KUMAR SAHU
IASP 2026 Global Year theme of Neuropathic Pain: Yes
Co-Authors:
- DR DINESH KUMAR SAHU: MBBS, MD, FPM - JAGJIVAN RAM RAILWAY HOSPITAL
- DR KAILASH KOTHARI: MBBS, MD, FIPM - PAIN CLINIC OF INDIA
Ultrasound-guided Fluoroscopic-verified Lumbar TFESI: A Clinical Evaluation of Technique
Category
Poster
Description
Session Type: Posters
Room: Exhibit Hall EH102-103
28/10/2026