741: Ultrasound versus Craig’s formula for Measuring Subarachnoid Space Depth during Spinal Anesthesia.
Topic: Clinical Science
Subtopic: Non-specific to any diagnosis, Pharmacological treatments
Background and Aims: Spinal anesthesia is a commonly performed regional anesthetic technique in surgeries involving the lower abdomen and lower limbs. A pre – puncture estimate of the subarachnoid space depth(SSD) is critical for administering spinal anesthesia to reduce unsuccessful and repeated attempts as well as post anesthetic complications.1 Traditional anthropometric calculations for the same such as Craig’s formula have been deviced for a quick guide for the depth of needle placement2 , while ultrasound provides an individualized, image-guided, estimation of subarachnoid space depth. 3
We compare the accuracy of Craig’s formula with ultrasound guidance in predicting SSD in patients undergoing Spinal Anaesthesia and also determine the correlation between Body Mass Index and SSD as secondary outcome.
Methods: A total of 60 patients aged 18–65 years, with ASA grades I & II posted for elective surgeries under spinal anaesthesia were included in the study. They underwent pre-anaesthetic evaluation and required laboratory investigations. SSD was estimated for each patient by three methods. Ultrasound estimation of SSD was done at the L3–L4 interspace in the transverse spinous process view. Next, SSD was calculated using Craig’s formula i.e SSD(cm)= 0.03x Height (cm). For the actual subarachnoid space depth measurement, a Subarachnoid block was performed under aseptic precautions in the sitting position using a 25G Quincke spinal needle, and the actual needle insertion depth at successful dural puncture was measured. The actual SSD was compared with ultrasound and Craig’s formula estimations. Correlation with BMI was also assessed. Statistical analysis included paired t-test, Pearson correlation, and Bland–Altman analysis.
Results: The mean actual SSD was 5.58± 1.02 cm. The ultrasound guided mean SSD estimation came out to be 5.59± 1cm which was much closer to the mean actual SSD, as compared to the depth estimation by application of Craig’s formula (6.58±1.10cm) which was higher. There was minimal bias observed on USG (0.01 ± 0.10cm) while the Craig’s formula showed a significant positive bias (1.00±0.25cm). Mean absolute error was 0.10cm with ultrasound which was significantly low, whereas Craig’s formula demonstrated significantly high values (1.00cm, p<0.001). As for the secondary objective, Body Mass Index showed a positive correlation with Subarachnoid Space Depth(r= +0.68 , p<0.001).
Conclusions: USG demonstrated higher accuracy and strongest correlation to actual needle depth as compared to the anthropometric Craig’s formula. Hence it provides a safe, more reliable method of SSD estimation, allowing for an enhanced pre-procedural identification of the optimal needle insertion point, trajectory, and depth, thus reducing the number of attempts and post procedural complications. Additionally, as per the study, Body Mass Index showed positive correlation with SSD, indicating that increasing BMI is associated with a greater needle insertion depth during the spinal anesthesia.
References: 1. Prakash S, Mullick P, Chopra P, Kumar S, Singh R, Gogia AR. A prospective observational study of skin to subarachnoid space depth in the Indian population. Indian J Anaesth. 2014;58:165–70. doi: 10.4103/0019-5049.130819.
2. Girimurugan N, M S, Pavithira S, R L, V S. Actual depth of subarachnoid space - A correlation between subarachnoid space depth estimated by stocker’s formula, craig’s formula and ultrasound guided spinal anaesthesia in the lumbar region [Internet]. Indian J Clin Anaesth. 2022;9(1):4-7.
3. Ahamed M T, Sethuraman US, Arikrishnan T, Lazarus SP. Correlation Between Skin-to-Subarachnoid Space Depth in the Lumbar Region Measured by Ultrasound and Needle Insertion Depth: A Prospective Observational Study. Cureus. 2025; 8;17(9). doi: 10.7759/cureus.91826.
Presenting Author: Dr Sunil
Submitting Author: SUNIL SUNIL
Senior Author: Dr Deepa Kerketta Khurana
IASP 2026 Global Year theme of Neuropathic Pain: Yes
Co-Authors:
- Dr Deepa K Khurana: MD Anesthesia - Vardhaman Mahavir Medical College and Safdarjung Hospital
- Dr Dimple Pande: MD DNB Anesthesia - Vardhaman Mahavir Medical College and Safdarjung Hospital
- Dr Kavita Rani: MD Anesthesia - Vardhaman Mahavir Medical College
Ultrasound versus Craig’s formula for Measuring Subarachnoid Space Depth during Spinal Anesthesia.
Category
Poster
Description
Session Type: Posters
Room: Exhibit Hall EH102-103
29/10/2026
03:15 PM - 04:45 PM